Manual valve shut off, proper flame sense microamps, gas valve defective or gas valve turned off, defective hot surface iqniter, control qround continuity, Check for: Flame sensor must not be grounded, low inlet gas pressure, oxide buildup on flame sensor, Check for: leaky gas valve, stuck open qas valveįailure to ignite or flame sense lost while running. Check for: restricted vent, proper vent sizing, loose blower wheel, excessive wind, dirty filter, defective blower motor, defective switch or connections, inadequate combustion air supplyĪbnormal flame proving signal-Flame is proved while gas valve is de-energized. Limit circuit fault-a limit or flame rollout is open. Pressure switch did not close, or re-opened- Check for: excessive wind, proper vent size, defective inducer motor, low inducer voltaqe, defective pressure switch, inadequate combustion air supply, disconnected or obstructed pressure tubing, low inlet gas pressure, restricted vent, condensate cloqqed Pressure switch did not open, check for obstructed pressure tubing Concord 96G1E Furnace Error Codes Status LED There are detailed recommendations on what to check for and what to fix if you experience these flashes or signals. For example, Concord furnace 3 flashes mean problems with pressure, and Concord furnace 6 flashes mean ignition problems. With the description you can also get some advice on what to do in case of the breakdown. In the tables below you can find Concord Furnace error codes and their explanations.